Stuffing box removal, Remove the split stuffing box xhd, Remove the casing volute liner – Goulds Pumps XHD - IOM User Manual

Page 76

Advertising
background image

Maintenance

Stuffing box removal

Pump Model

Next step to follow

XHD

• The stuffing box is split and can be disassem-

bled prior to casing volute liner removal. Con-
tinue with the Remove the split stuffing box
step below.

XHD Value Option

• The stuffing box is integral to the seal cover.

Skip to the Remove the seal cover step.

Remove the split stuffing box XHD

NOTICE:
This section applies only to units equipped with a split stuffing box. If your unit is not equipped
with a split stuffing box, the seal cover /chamber will be removed at a later step.

1. Remove the shoulder bolts (328) that hold the two halves together.
2. Remove the hex head bolts (569L) that attach the split stuffing box (159) to the seal cover

(184).

3. Remove the split stuffing box halves (159).
4. Remove the split stuffing box gaskets (367B).
5. Remove the packing (106) and lantern ring (105). The lantern ring has a split cut that can

be widened to accommodate removal without permanently deforming the part.

Remove the casing volute liner

NOTICE:The casing volute liner can be removed individually using the following steps if there
is an expeller installed or if there is no expeller, then the gland casing, volute liner, and seal
cover can be removed as one assembly, using the instructions from the section

Optional

disassembly of gland half casing, volute liner, and seal cover

(page 77)

1. Support the casing volute liner (561) with a Goulds-provided volute liner hook attached to

the hoist.
A sling can also be routed through and around the discharge opening of the casing volute
liner for support for some discharge orientations.

2. Remove the casing volute liner retention nuts (357A) from the volute liner retention studs

(356K) at the back of the gland half casing (100D).