Maintenance

Model

Parts that are still attached

XHD

• Suction side liner (562)
• Adjustable seal ring (822)
• Hardware Square head adjusting bolts (356F)

and hex jam nuts (357A)

XHD Value Option

• Suction side liner (562)
• Hardware Hex head bolts/hex cap screws

1. Support the suction half casing (100A) with a hoist hook through the lifting lug. Tension the

hoist properly so the subassembly will be fully supported upon disengagement.

2. Remove the casing hex head nuts (600C) and flat washers (553) from the casing hex head

bolts (600A) and tapered alignment studs (600D).

3. Leave the tapered alignment studs (600D) secured in place. The studs will provide

guidance in removal of the subassembly.

4. Guide the suction half casing (100A, with attached components) free of tapered alignment

studs.

5. Remove the hex head casing bolts (600A) from the gland half casing (100D).
6. Remove the tapered alignment studs from the gland half casing (100D) using a metric stud

driver.

Remove the remaining suction half components

Pump model

Next step to follow

XHD

• Remove the suction side liner and adjustable

seal ring

• Remove the adjustable seal ring

XHD Value Option

• Remove the suction liner

XHD Installation, Operation, and Maintenance Manual