Maintenance
Grease recommendations
Use a lithium-based mineral-oil grease with a consistency of NLGI 2 with EP additives.
This table shows which brand and type of grease to use when lubricating the pump.
Brand
Grease type
Castrol
Castrol EPL2
Exxon
Unirex EP2
Lubriplate
SYN 1602
Mobil
Mobilux EP 2
Mobilux EP460
Shell
Alvania EP2
SKF
LGEP2
LGWA 2
Texaco
Multifak EP 2
Grease amounts
Initial grease in ounces (grams)
Regrease amount in ounces
Size
per bearing
(grams) per bearing
PF2 Outboard
107 (3.8)
27 (1.0)
PF2 Inboard
74 (2.6)
PF3 Outboard
298 (10.5)
44 (1.6)
PF3 Inboard
175 (6.2)
PF4 Outboard
1379 (48.6)
88 (3.1)
PF4 Inboard
1108 (39.1)
PF5 Outboard
1408 (49.7)
122 (4.3)
PF5 Inboard
1408 (49.7)
Regrease the grease-lubricated bearings
NOTICE:
Make sure that the grease container, the greasing device, and the fittings are clean. Failure to
do this can result in impurities entering the bearing housing when you regrease the bearings.
1. Wipe dirt from the grease fittings(319H).
2. Fill both of the grease cavities through the fittings with a recommended grease until the
fresh grease comes out of the relief fittings (319Y).
3. Make sure that the grease retention rings (253) are seated in the bearing housing.
If they are not, press them in place with the drains located at the bottom.
4. Wipe off any excess grease.
5. Recheck the alignment.
The bearing temperature usually rises after you regrease due to an excess supply of grease.
Temperatures return to normal in about two to four operating hours as the pump runs and
purges the excess grease from the bearings.