Commissioning, startup, operation, and shutdown, Preparation for startup – Goulds Pumps XHD - IOM User Manual

Page 42

Advertising
background image

Commissioning, Startup, Operation, and Shutdown

Commissioning, Startup, Operation, and
Shutdown

Preparation for startup

DANGER:
Avoid death or serious injury. Explosion and/or seizure of pump can cause fire and/or burns. Never
operate pump past the pressure and temperature limits shown on the nameplate on the pump.

WARNING:

• Failure to follow these precautions before you start the unit will lead to serious personal injury and

equipment failure.

• Do not operate the pump below the minimum rated flows or with the suction or discharge valves

closed. These conditions can create an explosive hazard due to vaporization of pumped fluid and
can quickly lead to pump failure and physical injury.

• Avoid death or serious injury. Leaking fluid can cause fire and/or burns. Operating the pump above

maximum rated flow shown on the pump curve leading to an increase in horsepower and vibration
along with an increase in NPSHr resulting in mechanical seal and/or shaft failure and/or loss of
prime.

• Avoid death or serious injury. Leaking fluid can cause fire and/or burns. Speed of pump must reach

2000 rpm for 2 pole motors and 1000 rpm for 4 pole motors within 10 seconds or an increase in
vibration and rotor deflection and decrease in rotor stability leading to mechanical seal and/or shaft
failure and/or pump seizure can occur.

• Always disconnect and lock out power to the driver before you perform any installation or

maintenance tasks. Failure to disconnect and lock out driver power will result in serious physical
injury.

• Operating the pump in reverse rotation can result in the contact of metal parts, heat generation, and

breach of containment.

• Avoid death or serious injury. Explosion and/or seizure of pump can cause fire and/or burns. Assure

balance line is installed and either piped to the pump suction or back to the suction vessel to avoid
vaporization of pumped fluid.

DANGER:
Avoid death or serious injury. Leaking fluid can cause fire and/or burns. Assure all openings are sealed
off prior to filling pump.

Precautions

NOTICE:

• Verify the driver settings before you start any pump.

• Make sure that the warm-up rate does not exceed 2.5°F (1.4°C) per minute.

• Risk of damage to the mechanical seal or shaft sleeve on units supplied with cartridge

mechanical seals. Prior to startup, make sure to tighten the set screws in the seal locking
ring and remove the centering clips.

You must follow these precautions before you start the pump:

• Flush and clean the system thoroughly to remove dirt or debris in the pipe system in order

to prevent premature failure at initial startup.

• Bring variable-speed drivers to the rated speed as quickly as possible.

• If temperatures of the pumped fluid will exceed 200°F (93°C), then warm up the pump prior

to operation. Circulate a small amount of fluid through the pump until the casing
temperature is within 100°F (38°C) of the fluid temperature. Accomplish this by flowing

40

XHD Installation, Operation, and Maintenance Manual

Advertising