5 commissioning, 5commissioning – Festo Линейные модули HMP User Manual

Page 22

Advertising
background image

HMP−...−KP−...

Festo HMP−...−KP−... 0408b English

22

5

Commissioning

Definition
Moving mass = work load + fastening elements

Warning
Danger of injury to fingers.

S Ensure that in the positioning range of

the pressurized HMP−...:
ć nobody can place his/her hand in the

path of the guide tube.

ć no objects are in the path of the piston

rod.

Please note
The actuators will be considerably accelerated.

S Ensure that the linear module is pressurized only in the park position when

clamping is released. Movement against a non−pressurized chamber will
create an acceleration which can damage the linear module.

The actuators may perform sudden unexpected movements.

S Avoid exceeding the static holding force (see Technical Specifications).

The clamped guide tube may move approx. 1 ... 2 mm due to manufacturing
tolerances.

S

Comply with the commissioning instructions for the linear module HMP−... .

Starting the linear module:

S

Exhaust the linear module.

1. Push the guide tube by hand into the defined parking position (e. g. the end

position when retracted). You must press the manual override of the clamping
unit at the same.

2. First pressurize the compressed air connection for the parking position on the

linear module, and then on the clamping unit.

Fig. 21

Advertising