6 operation, 6operation – Festo Линейные модули HMP User Manual

Page 23

Advertising
background image

HMP−...−KP−...

Festo HMP−...−KP−... 0408b English

23

6

Operation

When performing adjustment work (e.Ăg. adjusting shock absorbers):

Please note
Deformed components may cause a functional failure.

S Make sure that no transverse forces are applied on housing 2, or on the

clamping rod of the HMP−...−KP.

If a sudden pressure drop occurs:

S

Check the function of the HMP−...−KP−...

without work load as follows:

ć Exhaust the linear module HML−...
ć Exhaust the clamping unit
ć Push the guide rod by hand into a parking position (press the manual

override at the same time)

ć Pressurize the parking position on the HMPL−...
ć Pressurize the linear module in the stroke direction.

The guide tube may move max. 1 ... 2 mm.

ć Exhaust the linear module

To

clamp the guide tube:

S

Carry out the following steps:

1. Pressurize the compressed air connection of the park position on the linear

module.

2. Exhaust clamping unit and then linear module.

To

move the linear module out of a parking position:

S

First pressurize the compressed air connection for the parking position on the
linear module, and then on the clamping unit.

If there is a change in the work load mass:

S

Compare the permitted loads with your actual application.