HSP−...−AP/A S

Festo HSP−...−AP/AS 0508a English

52

S

Check the cushioning elements and spring clamping elements (type designaĆ
tion see Accessories") for the following signs of wear:

Test

Spring clamping
element

1

Shock absorber

2

(...−AP)

Rubber buffer

2

(...−AS)

Test cycle

Every 2 million strokes (approx.Ăevery 2 months)

1)

Sign of wear

Play of the vertical
guide rail in the end
positions in a
horizontal direction

Oil leakage; hard
knocking; stop plunger
remains in the
retracted end position
or moves away from it
only hesitantly.

Hard knocking

2)

Replacement cycle

After 5 million cycles

Every 10 million strokes (approx 1 year)

1)

1)

At 0.5 Hz in dual operation mode.

2

) The rubber buffers in the fixed stops are only to reduce noise.

S

Check to see if more frequent tests are required. This may be the case with:

ć higher temperatures
ć excessive dirt
ć solvent liquids or fumes.

Please note
If the load changes, repeat the test taking the modified work load into
consideration.

Ĉ End position adjustment (chapter Fitting")

Ĉ Setting the positioning speed (chapter Commissioning")

Please note
HSP−...−A S with an electromotor:
Moving to the fixed stop (Ă

2 in fig. 1) generates sudden loadings in the drive

chain. This can lead e.g. to gear damage.

S Move to the fixed stops only with low energy or use a drive chain which can

withstand sudden loadings. The rubber buffers in the fixed stops are only to
reduce noise.