HSP−...−AP/A S
Festo HSP−...−AP/AS 0508a English
55
Replacing the rubber buffers in the fixed stops (HSP−...−AS):
1. Switch off the power supply of the drive.
2. Remove the protective cover.
3. Use a suitable tool to remove the rubber buffer of the fixed stop (e.g. screwdriĆ
ver, pliers).
4. Press the new rubber buffer into the fixed stop.
5. Fasten the protective cover.
Fig. 25