CS1630/31

40

DS954F3

6.27 Configuration 45 (Config45)

Address 77

6.28 Configuration 46 (Config46)

Address 78

7

6

5

4

3

2

1

0

-

-

-

-

-

-

VDIFF_LAT

MAX_CUR

Number

Name

Description

[7:2]

-

Reserved

[1]

VDIFF_LAT

Selects if the V

Diff

fault is to be a latched type fault.

0 = Unlatched fault
1 = Latched fault

[0]

MAX_CUR

Configures the second stage to draw maximum power when the boost output
voltage exceeds boost overvoltage protection threshold V

BST

>

V

BOP(th)

, trig-

gering a boost overvoltage fault.

0 = Disable
1 = Enable

7

6

5

4

3

2

1

0

-

-

-

-

WAKEUP3

WAKEUP2

WAKEUP1

WAKEUP0

Number

Name

Description

[7:4]

-

Reserved

[3:0]

WAKEUP[3:0]

Configures the 8-bit code value corresponding to temperature threshold
Temp

Wakeup

. Upon power-up the system will enter an external overtempera-

ture fault disabling the power train, unless the external temperature measured
at the external NTC is below Temp

Wakeup

. If the temperature drops below this

threshold, the device will clear all overtemperature faults. The setting is an off-
set to Temp

eOTP

(see “Configuration 59 (Config59) – Address 91” on page 48

for configuring Temp

eOTP

).

The equation above is setting 8-bit code, CODE

TEMPWakeup

, corresponding to

temperature Temp

Wakeup

, which is in degrees Celsius. The wakeup tempera-

ture code is configured as an offset from the eOTP temperature code and the
shutdown temperature code is configured as an offset from the wakeup tem-
perature code; Temp

eOTP

< Temp

Wakeup

< Temp

Shutdown

.

CODE

TEMPWakeup

CODE

TEMPeOTP

WAKEUP

+

[3:0] 4

=