Characteristics and specifications, Electrical characteristics, 1 electrical characteristics – Cirrus Logic CS1631 User Manual
Page 6

CS1630/31
6
DS954F3
3. CHARACTERISTICS AND SPECIFICATIONS
3.1 Electrical Characteristics
Typical characteristics conditions:
• T
A
= 25ºC, V
DD
= 12V, GND = 0V
• All voltages are measured with respect to GND.
• Unless otherwise specified, all currents are positive
when flowing into the IC.
Minimum/Maximum characteristics conditions:
• T
J
= -40°C to +125°C, V
DD
= 11V to 17V, GND = 0V
Parameter
Condition
Symbol
Min
Typ
Max
Unit
VDD Supply Voltage
Operating Range
After Turn-on
V
DD
11
-
17
V
Turn-on Threshold Voltage
V
DD
Increasing
V
ST(th)
-
8.5
-
V
Turn-off Threshold Voltage (UVLO)
V
DD
Decreasing
V
STP(th)
-
7.5
-
V
Zener Voltage
I
DD
= 20mA
V
Z
18.5
-
19.8
V
VDD Supply Current
Startup Supply Current
V
DD
<V
ST(th)
I
ST
-
-
200
A
Operating Supply Current
C
L
= 0.25nF, F
sw
60 kHz
-
5.8
-
mA
Reference
Reference Current
CS1630
CS1631
V
BST
= 200 V
V
BST
= 400 V
I
ref
-
-
133
133
-
-
A
A
Boost
Maximum Switching Frequency
f
BST(Max)
-
-
200
kHz
Clamp Current
I
CLAMP
-
-3.8
-
mA
Dimmer Attach Peak Current
CS1630
CS1631
108
V
line
132
207
V
line
253
-
-
590
508
-
-
mA
mA
Boost Zero-current Detect
BSTZCD Threshold
V
BSTZCD(th)
-
200
-
mV
ZCD Sink Current
I
BSTZCD
-2
-
-
mA
BSTAUX Upper Voltage
I
BSTZCD
= 1mA
-
V
DD
+0.6
-
V
Boost Protection
Clamp Turn-on
CS1630
CS1631
108
V
line
132
207
V
line
253
-
-
146.7
141.7
-
-
A
A
Second Stage Zero-current Detect
FBZCD Threshold
V
FBZCD(th)
-
200
-
mV
ZCD Sink Current
I
FBZCD
-2
-
-
mA
FBAUX Upper Voltage
I
FBZCD
= 1mA
-
V
DD
+0.6
-
V
Second Stage Current Sense
Peak Control Threshold
V
Pk_Max(th)
-
1.4
-
V
Delay to Output
-
-
100
ns