34 configuration 52 (config52) – address 84 – Cirrus Logic CS1631 User Manual

Page 44

Advertising
background image

CS1630/31

44

DS954F3

6.34 Configuration 52 (Config52)

Address 84

7

6

5

4

3

2

1

0

COP_THRES6 COP_THRES5 COP_THRES4 COP_THRES3 COP_THRES2 COP_THRES1 COP_THRES0

COP_INT

Number

Name

Description

[7:1]

COP_THRES[6:0]

Value used to determine the COP Filter Threshold. The clamp is sampled
every 20

s and over the selected interval is compared to COP time-on

threshold, T

ON(th)

to determine if an COP fault has occurred.

For a 1 second interval:

For a 2 second interval:

[0]

COP_INT

Configures the time interval to check for a boost stage COP fault.

0 = 1 second interval
1 = 2 second interval

TON th

 

COP_THRES

[6:0] 5.12ms

 2.56ms

+

=

T

ON th

 

COP_THRES

[6:0] 10.24ms

 5.12ms

+

=

Advertising
This manual is related to the following products: