3.3 Power Line Calibration Characteristics

Typical characteristics conditions:

• T

A

= 25ºC, V

DD

= 12V, GND = 0V

• All voltages are measured with respect to GND.
• Unless otherwise specified, all current is positive when

flowing into the IC.

Minimum/Maximum characteristics conditions:

T

J

= 25ºC, V

DD

= 11V to 17V, GND = 0V

Notes:

6.

The CS1630/31 supports leading-edge phase-cut waveforms only for power line calibration.

7. Range is recommended for power line calibration operation only.

Parameter

(Note 6)

Min

Typ

Max

Units

Input Line Frequency

(Note 7)

47

50/60

63

Hz

Input Voltage

(Note 7)

CS1630
CS1631

114

218

120
230

126
242

V
V

Dual-bit 00 (“00”)

24

34

44

Degrees

Dual-bit 01 (“01”)

52

62

72

Degrees

Dual-bit 10 (“10”)

108

118

128

Degrees

Dual-bit 11 (“11”)

136

146

156

Degrees

Special Character (SC)

80

90

100

Degrees