CS1630/31

DS954F3

41

6.29 Configuration 47 (Config47)

Address 79

7

6

5

4

3

2

1

0

OCP

OLP

OVP

BOP

COP

LLP

EEOTP

IOTP

Number

Name

Description

[7]

OCP

Configures second stage primary side overcurrent protection.

0 = Enable
1 = Disable

[6]

OLP

Configures second stage primary side open loop protection (R

Sense

Short Pro-

tection).

0 = Enable
1 = Disable

[5]

OVP

Configures second stage secondary side overvoltage protection (Output Open
Circuit Protection).

0 = Enable
1 = Disable

[4]

BOP

Configures boost overvoltage protection.

0 = Enable
1 = Disable

[3]

COP

Configures clamp overpower protection.

0 = Enable
1 = Disable

[2]

LLP

Configures line link protection.

0 = Enable
1 = Disable

[1]

EEOTP

Configures external overtemperature protection.

0 = Enable
1 = Disable

[0]

IOTP

Configures internal overtemperature protection.

0 = Enable
1 = Disable