CS1630/31

42

DS954F3

6.30 Configuration 48 (Config48)

Address 80

6.31 Configuration 49 (Config49)

Address 81

7

6

5

4

3

2

1

0

OCP_BLANK3 OCP_BLANK2 OCP_BLANK1 OCP_BLANK0 OLP_BLANK2 OLP_BLANK1 OLP_BLANK0 IOTP_SAMP

Number

Name

Description

[7:4]

OCP_BLANK[3:0]

Configures fixed time-blanking interval t

OCP

for overcurrent protection

(OCP). The value is an unsigned integer in the range of 0

value15.

[3:1]

OLP_BLANK[2:0]

Configures fixed time blanking interval t

OLP

for open loop protection (OLP)

and sense resistor protection. The value is an unsigned integer in the range
of 0

value7.

[0]

IOTP_SAMP

Sample internal temperature sensor at a slower rate when not in internal
overtemperature state (iOTP fault state). Recommended to set bit
IOTP_SAMP to sample slow.

0 = Sample fast
1 = Sample slow

7

6

5

4

3

2

1

0

OCP_CNT2

OCP_CNT1

OCP_CNT0

OCP_LAT

OLP_CNT2

OLP_CNT1

OLP_CNT0

OLP_LAT

Number

Name

Description

[7:5]

OCP_CNT[2:0]

Sets the second stage OCP fault counter threshold used when declaring a
fault.

0 = Force OCP fault (debug only)
1-7= Number of times an OCP fault has to occur consecutively.

[4]

OCP_LAT

Configures OCP fault type.

0 = Unlatched fault
1 = Latched fault

[3:1]

OLP_CNT[2:0]

Sets the second stage OLP fault counter threshold used when declaring a
fault.

0 = Force OLP fault (debug only)
1-7= Number of times an OLP fault has to occur consecutively before the
IC will enter a fault state.

[0]

OLP_LAT

Configures OLP fault type.

0 = Unlatched fault
1 = Latched fault

t

OCP

150ns

OCP_BLANK

+

[3:0] 50ns

=

t

OLP

1

s

OLP_BLANK

+

[2:0] 0.5

s 

=