Cirrus Logic CS5373A User Manual

Page 35

Advertising
background image

CS5373A

DS703F2

35

Full-scale Accuracy - Variation in the measured output voltage from the theoretical full-scale output voltage at
1x attenuation. The following formula is used to calculate full-scale accuracy:

Relative Accuracy - Variation in the measured output voltage from the theoretical attenuated output voltage at
each of the attenuation ranges. The following formula is used to calculate relative accuracy:

Full Scale Drift - The variation of the measured full-scale voltage across the specified temperature range.

Common Mode Drift - The variation in the measured common mode voltage across the specified temperature
range.

full scale accuracy =

measured full scale voltage - theoretical full scale voltage

theoretical full scale voltage

(

(

•100%

|

|

relative accuracy =

measured attenuated voltage - theoretical attenuated voltage

theoretical attenuated voltage (relative to the measured full scale voltage)

(

(

•100%

|

|