16.1.8 Pause-DR

The pause state allows the test controller to tempo-
rarily halt the shifting of data through the current
test data register.

16.1.9 Exit2-DR

This is a temporary state. The test data register se-
lected by the current instruction retains its previous
value.

16.1.10 Update-DR

The Boundary Scan Register is provided with a
latched parallel output to prevent changes while
data is shifted in response to the EXTEST and
SAMPLE/PRELOAD instructions. When the TAP
controller is in this state and the Boundary Scan
Register is selected, data is latched into the parallel
output of this register from the shift-register path

on the falling edge of TCK. The data held at the
latched parallel output changes only in this state.

16.1.11 Select-IR-Scan

This is a temporary controller state. The test data
register selected by the current instruction retains
its previous state.

16.1.12 Capture-IR

In this controller state, the instruction register is
loaded with a fixed value of “01” on the rising edge
of TCK. This supports fault-isolation of the board-
level serial test data path.

16.1.13 Shift-IR

In this state, the shift register contained in the in-
struction register is connected between TDI and
TDO and shifts data one stage towards its serial
output on each rising edge of TCK.

1

0

Test-Logic-Reset

Run-Test/Idle

Select-DR-Scan

Capture-DR

Shift-DR

Exit1-DR

Pause-DR

Exit2-DR

Update-DR

Select- I R-Scan

Capture- IR

Shift- IR

Exit1- IR

Pause- IR

Exit2- IR

Update- IR

0

1

1

1

1

1

1

1

1

1

1

1

1

1

1

0

0

0

0

0

0

0

0

0

0

0

0

0

1

0

Figure 15. TAP Controller State Diagram

Advertising