18.1 Transformer Specifications

Recommended transformer specifications are
shown in

Table 15

. Any transformer used with the

CS61880 should meet or exceed these specifica-
tions.

18.2 Crystal Oscillator Specifications

When a reference clock signal is not available, a
CMOS crystal oscillator may be used as the refer-
ence clock signal. The oscillator must have a mini-
mum symmetry of 40-60% and minimum stability
of + 100 ppm.

18.3 Line Protection

Secondary protection components can be added to
the line interface circuitry to provide lightning
surge and AC power-cross immunity. For addition-
al information on the different electrical safety
standards and specific applications circuit recom-
mendations, refer to Application Note AN034, Sec-
ondary Line Protection for T1 and E1 Cards
.

Table 15. Transformer Specifications

Descriptions

Specifications

Turns Ratio Receive

1:2

Turns Ratio Transmit

1:1.15

Primary Inductance

1.5 mH min @ 1024 kHz

Primary Leakage Induc-
tance

0.3

µ

H max @ 1024 kHz

Secondary leakage Induc-
tance

0.4

µ

H max @ 1024 kHz

Inter winding Capacitance

18 pF max, primary to

secondary

ET-Constant

16 V -

µ

s min