Lenovo Secure Managed Client User Manual

Page 59

Advertising
background image

Table

6.

Light

and

buzzer

interpretations

(continued)

LED/buzzer

State

Related

Meaning

Action

Fast

blink

(alternating

every

half

second)

Faster

beep

(1.5

seconds

beep,

0.5

seconds

silence).

No

fan

light

constant.No

beep

if

muted.

Critical

state

-

usually

temperature

near

edge

of

operating

range

Measure

ambient

temperature

and

increase

if

too

cold

or

decrease

if

too

hot.

If

failure

is

still

present,

check

for

a

failing

fan

that

also

has

a

broken

light.

Faster

beep,

more

than

one

fan

light

on

or

a

single

PSU

fan

light

on.

No

beep

if

muted.

Fans

broken

or

out

of

tolerance.

Replace

fans

immediately.

Constant

on

Constant

-

no

fan

lights

are

on

constant

Failure

state

-

temperature

in

range

where

damage

could

occur

Measure

ambient

temperature

and

increase

if

too

cold

or

decrease

if

too

hot.

If

failure

is

still

present,

check

for

a

failing

fan

that

also

has

a

broken

light.

Constant

-

multiple

fan

lights

are

on

constant

Fans

broken

or

out

of

tolerance

Replace

fans

immediately.

Decrease

ambient

temperature

Fan

light

Constant

on

Varying

levels

of

beep

and

chassis

fault

light

setting.

No

beep

if

muted.

Fan

broken

or

out

of

tolerance.

Replace

fans

immediately.

Drive

light

(amber)

Constant

on

Varying

levels

of

beep

and

chassis

fault

-

usually

slow

beep

and

slow

flash.

No

beep

if

muted.

Drive

faulty

Replace

drive

Front

operator's

panel

ID

LED

Flashing

Ops

panel

ident

on

Buzzer

Off

Front

operator's

panel

fault

LED

off

No

issues

Off

Front

operator's

panel

fault

LED

flashing

or

constant

Muted

Intermittent

short

beep

(0.5

second

beep

every

32

seconds)

Various

front

operator's

panel

fault

light

flash

states

Fault

has

occurred

and

system

is

muted

but

in

remind

mode

Check

fault

status

using

operator's

panel

fault

LED

settings

and

remedy.

Slow

beep

(half

second

beep

every

8

seconds)

Front

operator's

panel

fault

LED

slow

blink

(0.5

seconds

on,

3.5

seconds

off)

Warning

mode

Faster

beep

(1.5

seconds

beep,

0.5

second

silence)

Front

operator's

panel

fault

LED

fast

blink

(alternating

every

half

second)

Critical

mode

Chapter

7.

Troubleshooting

and

problem

solving

53

Advertising