3 ac characteristics, Ac characteristics, Figure 9-2 – AMD Geode SC1201 User Manual

Page 376: General drive level and measurement points, Table 9-11

Advertising
background image

376

AMD Geode™ SC1200/SC1201 Processor Data Book

Electrical Specifications

32579B

9.3

AC Characteristics

The tables in this section list the following AC characteris-
tics:

Output delays

Input setup requirements

Input hold requirements

Output float delays

Power-up sequencing requirements

The default levels for measurement of the rising clock edge
reference voltage (V

REF

), and other voltages are shown in

Table 9-11. Input or output signals must cross these levels
during testing. Unless otherwise specified, all measure-
ment points in this section conform to these default levels.

All AC tests are at V

IO

= 3.14V to 3.46V (3.3V nominal),

T

C

= 0

o

C to 85

o

C, C

L

= 50 pF, unless otherwise specified.

Figure 9-2. General Drive level and Measurement Points

Table 9-11. Default Levels for Measurement of

Switching Parameters

Symbol

Parameter

Value (V)

V

REF

Reference Voltage

1.5

V

IHD

Input High Drive Voltage

2.0

V

ILD

Input Low Drive Voltage

0.8

V

OHD

Output High Drive Voltage

2.4

V

OLD

Output Low Drive Voltage

0.4

CLK

Outputs

Inputs

V

IHD

V

ILD

V

REF

Valid Input

Valid Output

n+1

Valid Output

n

V

REF

V

REF

V

ILD

V

IHD

Min

Max

Legend: A = Maximum Output or Float Delay Specification

B = Minimum Output or Float Delay Specification
C = Minimum Input Setup Specification
D = Minimum Input Hold Specification

T

X

B

A

C

D

V

OHD

V

OLD

Advertising