Table 9-30, Ide ultradma data burst timing parameters – AMD Geode SC1201 User Manual

Page 406

Advertising
background image

406

AMD Geode™ SC1200/SC1201 Processor Data Book

Electrical Specifications

32579B

Table 9-30. IDE UltraDMA Data Burst Timing Parameters

Symbol

Parameter

Mode 0

Mode 1

Mode 2

Unit

Comments

Min

Max

Min

Max

Min

Max

t

2CYC

Typical sustained average two cycle time

240

160

120

ns

Two cycle time allowing for clock variations
(from rising edge to next rising edge or from
falling edge to next falling edge of STROBE)

235

156

117

ns

t

CYC

Cycle time allowing for asymmetry and clock
variations (from STROBE edge to STROBE
edge)

114

75

55

ns

t

DS

Data setup time (at recipient)

15

10

7

ns

t

DH

Data hold time (at recipient)

5

5

5

ns

t

DVS

Data valid setup time at sender (from data
bus being valid until STROBE edge)

70

48

34

ns

t

DVH

Data valid hold time at sender (from
STROBE edge until data may become
invalid)

6

6

6

ns

t

FS

First STROBE time (for device to first negate
IDE_IRDY[0:1] (DSTROBE[0:1]) from
IDE_IOW[0:1]# (STOP[0:1]) during a data in
burst)

0

230

0

200

0

170

ns

t

LI

Limited interlock time

0

150

0

150

0

150

ns

Note 1

t

MLI

Interlock time with minimum

20

20

20

ns

Note 1

t

UI

Unlimited interlock time

0

0

0

ns

Note 1

t

AZ

Maximum time allowed for output drivers to
release (from being asserted or negated)

10

10

10

ns

t

ZAH

Minimum delay time required for output driv-
ers to assert or negate (from released state)

20

20

20

ns

t

ZAD

0

0

0

ns

t

ENV

Envelope time (from IDE_DACK[0:1]# to
IDE_IOW[0:1]# (STOP[0:1]) and
IDE_IOR[0:1]# (HDMARDY[0:1]#) during
data out burst initiation)

20

70

20

70

20

70

ns

t

SR

STROBE to DMARDY time (if DMARDY# is
negated before this long after STROBE
edge, the recipient receives no more than
one additional data WORD)

50

30

20

ns

t

RFS

Ready-to-final-STROBE time (no STROBE
edges are sent this long after negation of
DMARDY#)

75

60

50

ns

t

RP

Ready-to-pause time (time that recipient
waits to initiate pause after negating
DMARDY#)

160

125

100

ns

t

IORDYZ

Pull-up time before allowing IDE_IORDY[0:1]
to be released

20

20

20

ns

t

ZIORDY

Minimum time device waits before driving
IDE_IORDY[0:1]

0

0

0

ns

t

ACK

Setup and hold times for IDE_DACK[0:1]#
(before assertion or negation)

20

20

20

ns

t

SS

Time from STROBE edge to negation of
IDE_DREQ[0:1] or assertion of
IDE_IOW[0:1]# (STOP[0:1]) (when sender
terminates a burst)

50

50

50

ns

Note 1.

t

UI

, t

MLI

, and t

LI

indicate sender-to-recipient or recipient-to-sender interlocks, that is, one agent (either sender or recipient) is wait-

ing for the other agent to respond with a signal before proceeding. t

UI

is an unlimited interlock with no maximum time value. t

MLI

is a limited timeout with a defined minimum. t

LI

is a limited time-out with a defined maximum.

Advertising