c. Holding the end cap in one hand, pull the outer

pump handle until the piston is fully withdrawn

inside the end cap.

3

Returning plungers into cylinders

a. After lightly oiling the top inside edge of the

cylinder, position the plunger assembly on the

cylinder with one hand. With the palm of the

other hand, firmly push the plunger down fully.

b. Tighten end cap assembly onto cylinder

assembly using Allen key.

c. Remove the sleeve from the inner piston and

discard. Lightly oil the inside edge of the hollow

outer piston shaft and then gently ease the

piston inside. Refit the gauges.