General maintenance, Pump calibration - model 53 pd, Outer pump calibration – Fluid Management 53PD Blendorama User Manual User Manual

Page 39: Inner pump calibration

Advertising
background image

Fluid Management Customer Service 1 . 800 . 462 . 2466

Blendorama Dispenser | 37

1

Outer pump calibration

Recalibration of the pump is necessary if either of the original gauges have been replaced by another (for any

reason). It is not required if only a gauge scale detail (Label) has been replaced. When recalibrating the pump,

please leave the pump/canister fixed in place on the machine.

Tools required: 1 x Allen (hex) key 3/32” A/F

a. Calibrate the outer pump first by removing the

inner pump (red) gauge and lifting the red pump

handle approximately 4” or 100mm. Lock the

black outer pump gauge into the top hole (zero

position).

b. Using the Allen key, undo the calibration

grubscrew until free movement can be felt

between the outer pump (black) handle and the

outer gauge knob.

c. Carefully wind the grubscrew down until no free

movement is felt between the outer pump handle

and the gauge knob, being careful not to over-

adjust.

When correctly adjusted there should be a

slight binding felt on the black gauge locking pin

(as the locking pin shaft enters the hole in the

gauge).

2

Inner pump calibration

a. Calibrate the inner pump by lowering red pump

handle fully, then refitting the inner (red) gauge

and setting it to zero.

b. Undo the calibration grubscrew in the red pump

handle until the handle has movement.

c. Carefully wind the grubscrew down until no free

movement is felt between the red pump handle

and the red gauge knob, being careful not to

over-adjust. When correctly adjusted there

should be a slight binding felt on the red gauge

locking pin (as the locking pin shaft enters the

hole in the gauge).

General Maintenance

Pump calibration - Model 53 PD