General maintenance, Pump calibration - model 25 pd (continued) – Fluid Management 53PD Blendorama User Manual User Manual

Page 38

Advertising
background image

36 | Blendorama Dispenser

Fluid Management Customer Service 1 . 800 . 462 . 2466

2

Inner pump calibration

a. To calibrate the inner (red) plunger, refit the inner

(red) gauge and plunger removed in step (1). Set

the inner (red) gauge to zero.

b. Using the Allen key, undo the calibration

grubscrew in the red pump handle until free

movement can be felt in the handle. Carefully

wind the grubscrew back down until no free

movement can be felt between the red pump

handle and the red gauge knob. Be careful not

to over-adjust.

c. The pump is now calibrated.

General Maintenance

Pump calibration - Model 25 PD (continued)

Advertising