Troubleshooting – Fluid Management 53PD Blendorama User Manual User Manual

Page 40

Advertising
background image

38 | Blendorama Dispenser

Fluid Management Customer Service 1 . 800 . 462 . 2466

Most of the problems listed in this section can be prevented by daily cleaning and by purging the nozzle.
See the

Maintenance, Care and Use section in this manual for instructions.

Use the chart below to locate the problem and perform the recommended actions in the last column.

Contact Fluid Management Customer Service if you are unable to find a resolution.

Symptom

Cause

Action

Colorant intermittently spurts from the

nozzle during discharge

Air bubbles in the colorant

Operate the pump several times

without opening the valve to drive the

air back into the canister. Then allow

the colorant to sit for several minutes

to allow the bubbles to escape.

A drop of colorant falls from the nozzle

when the valve is opened even when

the pump is not operated

Air is trapped in the cylinder assembly Operate the pump several times

without opening the valve to drive the

air back into the canister. Then allow

the colorant to sit for several minutes

to allow the bubbles to escape.

The end cap twists or lifts during

operation

End-cap grub-screws are loose

Lightly tighten the 2 grub-screws in

the end-cap (for 53 Series tighten the

end-cap sleeve) until the end cap can

no longer be twisted by hand.

Canister is loose on turntable

Loose fixing screws

Tighten fixing screws with a Phillips

head screwdriver.

Colorant appears on the piston shaft,

piston and/or gauges

Worn seals

Replace seals.

Colorant does not dispense easily

Nozzle blocked

Remove nozzle and clean in warm

soapy water.

Colorant still does not dispense easily High viscosity of colorant

Increase the size of the nozzle.

Colorant has hardened in the canister

and piston assembly

Canister and pump should be

removed, emptied, stripped and

cleaned thoroughly. Replenish only

with new colorant.

Agitation is not occurring

No power to the dispenser

Check that the unit is connected and

that there is power to the outlet.

Troubleshooting