Outer pump calibration

Recalibration of the pump is necessary if either of the original gauges have been replaced by another (for any

reason). It is not required if only a gauge scale detail (Label) has been replaced. When recalibrating the pump,

please leave the pump/canister fixed in place on the machine.

Tools required: 1 x Allen (hex) key 3/32” A/F

a. To calibrate the outer plunger, remove the inner

(red) gauge and inner (red) plunger and set the

outer (black) gauge to the zero position.

b. Using the Allen key, undo both calibration

grubscrews until free movement can be felt

between the outer (black) plunger handle and

the outer (black) gauge knob.

c. Carefully wind one grubscrew down until only

slight movement is felt between the outer pump

handle and the gauge knob. Then wind the other

grubscrew down until no free movement can be

felt, being careful not to over-adjust.

General Maintenance

Pump calibration - Model 25 PD