Troubleshooting gyromixer end user guide 19 – Fluid Management Miller GyroMixer User Manual

Page 23

Advertising
background image

TROUBLESHOOTING

GyroMixer End User Guide

19

Mixer will not shut off.

Damaged timer relay.

Replace timer relay.

Faulty connection to the potentiometer.

Tighten connection to potentiometer.

Damaged potentiometer.

Replace potentiometer.

Mixer hums, but will not run.

Insufficient current.

Verify mixer is correctly installed to a
dedicated line.

Something caught in mixer.

Check for obstructions.

Defective bearing in pulleys four arms or
main drive.

Check each bearing for roughness.
Replace if necessary.

Defective motor.

Replace motor.

Mixer squeaks at startup, but still
runs.

Belts loose.

Check V-belt and poly-V belt
tension. Tighten if necessary.

PROBLEM

POSSIBLE CAUSE

ACTION

Advertising