TROUBLESHOOTING

GyroMixer End User Guide

19

Mixer will not shut off.

Damaged timer relay.

•

Replace timer relay.

Faulty connection to the potentiometer.

•

Tighten connection to potentiometer.

Damaged potentiometer.

•

Replace potentiometer.

Mixer hums, but will not run.

Insufficient current.

•

Verify mixer is correctly installed to a
dedicated line.

Something caught in mixer.

•

Check for obstructions.

Defective bearing in pulleys four arms or
main drive.

•

Check each bearing for roughness.
Replace if necessary.

Defective motor.

•

Replace motor.

Mixer squeaks at startup, but still
runs.

Belts loose.

•

Check V-belt and poly-V belt
tension. Tighten if necessary.

PROBLEM

POSSIBLE CAUSE

ACTION