Fluid Management Miller GyroMixer User Manual

Page 31

Advertising
background image

SERVICE

GyroMixer End User Guide

27

REMOVING THE MOTOR

1.

Unplug the electrical cord.

2.

Remove the rear access panel and top cover by removing the screws.

3.

Loosen, but do not remove, the idler pulley.

4.

Remove the belt from the motor pulley.

5.

Loosen the screw holding the conduit box cover in place.

6.

Remove the conduit box cover in order to disconnect the following three

wires:

Brown (L1) and blue (L2) wires which are secured with wire nuts.

Ground wire held with in place with a green screw.

7.

Inside the conduit box, remove the nut securing the tubing connector to

the conduit box and separate the connector from the conduit box.

8.

Holding the motor securely, remove the four (4) screws holding the

motor to the motor mounting bracket. Save the screws. Discard the

motor.

9.

For reassembly purposes, measure the position of the motor drive pulley

before removing it from the driveshaft: measure from the face of the

motor to the edge of the pulley.

Note:

The key should be flush with the shaft.

10.

Loosen the motor drive pulley set screw and remove the pulley. Save the

circular push-on retaining ring for reassembly.

11.

Set the pulley aside for later use.

12.

Discard the old motor.

Advertising