Fluid Management Miller GyroMixer User Manual

Page 28

Advertising
background image

SERVICE

24

CAUTION:

To avoid breakage, do not over actuate the power
lever.

8.

After tightening the screws in step 7 and with the power lever still in the

ON position, slide the start switch bracket toward the front of the mixer

until fully depressed by the roller. Tighten the screws while the switch is

in this position.

9.

Replace the top cover and rear access panel. Tighten the screws.

10.

Restore the power.

REPLACING THE ROLLER

1.

Unplug the mixer.

2.

Open the sliding door.

3.

Remove the screw on each end of the roller bracket. Use a needle-nose

pliers to hold the plastic bushing while removing the Phillips screw.

4.

Remove and discard the old roller.

5.

Place the plastic bushings in the ends of the new roller.

6.

Place the roller on the roller bracket.

7.

Using the needle-nose pliers to keep the plastic bushing from rotating,

tighten the screws on the roller bracket.

8.

Close the sliding door.

9.

Restore power to the mixer.

INSTALLING THE UPPER TABLE PAD

1.

Unplug the electrical cord.

2.

Raise the sliding door.

3.

Turn the rotating assembly upside down.

4.

Use a scraper to loosen the pad around the edges.

5.

Pull off the old pad.

Advertising