Fluid Management Miller GyroMixer User Manual

Page 27

Advertising
background image

SERVICE

GyroMixer End User Guide

23

10.

Replace the rear access panel.

11.

Restore power.

ADJUSTING THE CLAMPING FORCE IN THE CLAMP HANDLE

1.

Unplug the unit.

2.

Load container into mixer.

3.

Clamp the container.

4.

Test the clamping force by pushing the container with two hands. If the

container moves, the clamping force must be adjusted as follows:

Remove the black plastic plug from the center of the clamp handle.

Using a needle-nose pliers, remove the cotter pin.

Tighten the locknut by turning it clockwise one or two revolutions.

Recheck the clamping force. If the container still moves when
clamped, tighten the nut until the pail does not move when clamped.

5.

When the clamping force is correct, place the cotter pin that was

removed in step 4 back into the mechanism.

6.

Place the plastic plug back into the center of the crank handle.

7.

Restore power to the mixer.

ADJUSTING THE DOOR LOCK LINKAGE AND START SWITCH

1.

Disconnect the power.

2.

Remove rear access panel.

3.

Remove the top cover by removing the screws holding it in place.

4.

Loosen the two (2) screws between the door lock linkage brackets.

5.

Loosen the two (2) screws in the start switch mounting bracket. (Only

for explosion-proof models.)

6.

Turn the power lever to the ON position.

7.

With the door locking bracket in a fully upright position against the

rubber stop, retighten the two (2) adjustment screws between the door

lock linkage brackets.

Advertising