 3      Installing  the  Air  Locker  

 

 

17

 

3.5

     

Assembling  the  Seal  Housing

 

 

 
 

 
 
 

 
 
 
 

 
 

 

 

 
 
 

 
 

 Figure  9.  

 
 
F

 Make  sure  the  grooves  and  airway  of  the  seal  housing  are  clean  

and  free  from  any  contaminants  (e.g.  water,  dirt,  metal  filings,  etc.).  

F

 Inspect  the  seal  housing  O-­rings  (supplied)  for  dirt,  damage  or  

other  conditions  which  might  cause  leaks.    

F

 Generously  lubricate  the  O-­rings  with  oil  prior  to  assembly,  then  

insert  them  into  the  grooves  of  the  seal  housing.  

 

 NOTE  :     When  assembling  the  O-­rings,  be  careful  not  to  leave  

them  twisted  when  seated  in  the  grooves  as  this  could  
cause  excessive  wear  and  leakage.    

 

F

 Lubricate  the  seal  housing  running  surface  on  the  Air  Locker  carrier  

with  oil.    Assemble  a  bearing  cup  onto  the  left-­hand  side  of  the  Air  
Locker
.  

F

 With  the  stepped  side  towards  the  bearing,  carefully  install  the  seal  

housing  by  sliding  it  all  of  the  way  onto  the  bearing  journal  with  a  
gentle  twisting  motion.    This  will  allow  the  O-­rings  to  engage  gently.  

 

 

 

IMPORTANT  :    

 

$PP0DVWHU6KLPLVVXSSOLHGIRUXVHZLWKWKH³WKLQ´EHDULQJFXS

(382A).  Do  noWXVHWKLVVKLPZLWKWKH³WKLFN´EHDULQJFXS -­S).  

 

 