3 installing the air locker, Reinstalling the bearing caps – ARB RD166 User Manual

Page 22

Advertising
background image

 3      Installing  the  Air  Locker  

 

 

20

 

 

3.7

     

Reinstalling  the  Bearing  Caps

 

 

 

F

 Install  the  bearing  caps  oriented  as  they  were  marked  before  they  

were  removed,  and  tighten  the  bearing  cap  bolts.    It  is  not  
necessary  to  torque  them  down  at  this  time.

 

F

 Check  that  some  clearance  exists  between  the  bearing  cap  and  the  

seal  housing  tube.    If  not,  the  bearing  cap  should  be  removed  and  
the  tube  re-­bent  for  adequate  clearance.  

F

 Tighten  all  bearing  cap  bolts  with  a  torque  wrench  to  the  torque  

VSHFLILHGLQ\RXUYHKLFOHPDQXIDFWXUHU¶VVHUYLFHPDQXDO  

 