And 22., depending, 5 mounting & connecting the electrical system, Dual air locker system – ARB RD166 User Manual

Page 37

Advertising
background image

 5      Mounting  &  Connecting  the  Electrical  System  

 

 

35

5.2.2.2

       

Dual  Air  Locker  System

     

 
F

 If  two  Air  Lockers  are  to  be  installed  in  the  system,  ARB  

recommends  that  the  switches  and  solenoids  be  wired  according  to  
figure  22.    For  safety  reasons,  this  configuration  allows  SOLENOID  
2  to  be  actuated  only  if  SOLENOID  1  is  already  on.  

F

 AttacKWKH³5($5$,5/2&.(5´VZLWFKFRYHUWR6:,7&+DQG

WKH³)5217$,5/2&.(5´VZLWFKFRYHUWR6:,7&+  

 

 NOTE  :     Refer  to  Figure  20.  for  the  correct  switch  terminal  

identification  and  switch  orientation.  

 

F

 Configure  SOLENOID  1  as  the  air  line  leading  to  the  rear  axle  Air  

Locker,  and  SOLENOID  2  as  the  air  line  leading  to  the  front  axle  Air  
Locker
.  

 

 
 

 
 

 
 

 
 

 

 
 

 
 

 
 

 
 

 

 Figure  22.  

DUAL  Air  Locker  SYSTEM  

 