Brother HE-800A User Manual

Page 42

Advertising
background image

HE-800A

5. OPERATION

34

Example 2: How to set a taper tack for the front tack pattern and an eyelet for the rear tack pattern to program number

10.

First, set parameter number 01 to "buttonhole

stitch (free) setting value 0".

1. Press the SELECT key (1) to change the mode to

automatic, test feed or manual mode.

2. Press the program No. keys (2) and (3) to select the

program number 10, and then press the ENTER

key (4).

3. Press the SELECT key (1) to change the mode to

program mode.

4. Press the program No. keys (2) and (3) to select the

parameter number 01.

5. Press the parameter keys (5) and (6) to select the

parameter setting value 0, and then press the

ENTER key (4).

Next, set parameter number 20 to "Taper tack

setting value 4".

6. Press the program No. keys (2) and (3) to select the

parameter number 20.

7. Press the parameter keys (5) and (6) to select the

parameter setting value 4, and then press the

ENTER key (4).

Next, set parameter number 30 to "Eyelet setting

value 3".

8. Press the program No. keys (2) and (3) to select the

parameter number 30.

9. Press the parameter keys (5) and (6) to select the

parameter setting value 3, and then press the

ENTER key (4).

An eyelet taper-tack buttonhole has now been set

for program No. 10.

10. Press the SELECT key (1) to change the mode to

automatic mode.