Brother HE-800A User Manual

Page 87

Advertising
background image

HE-800A

11. CHANGING FUNCTIONS USING THE MEMORY SWITCHES

79

ውው-. Memory switch table

The memory switch settings are effective for all programs.

No.

Setting items

Setting range

Unit

Default

00. Cutter

power

-1:

Light

0:

Light - Normal

1:

Normal

2:

Normal - Medium

3:

Medium

4:

Heavy

1 1

02.

Work clamp lifting speed

-4 - 4

1

0

03.

Work clamp lowering speed

-4 - 4

1

0

04.

Work clamp height when treadle is
depressed backward

1 - 13mm

1

13

05.

Work clamp height at neutral
position

1 - 13mm

1

10

06.

Soft press height

OFF, 0.1 - 8.0mm

0.1

OFF

07.

(*1)

Threshold value correction when

work clamp is lifted

-10 - 10

1

0

08.

(*1)

Threshold value correction when

work clamp is lowered

-10 - 10

1

0

09.

(*1)

Threshold value correction at start

-10 – 10

1

0

10.

Extension time for continuous
sewing

OFF, 100 – 1,000ms

100

OFF

11.

Home position return cycle

OFF, 1 – 10

1

1

12. Feed

timing

-10 – 10 ( x 0.24

q)

1 0

13.

Cutter dimension display during
automatic mode

ON: Cutter dimensions are displayed.
OFF: Production counter or bobbin

thread counter is displayed.

- OFF

14.

Program number changing enabled
when program lock is set

ON: Program numbers can be

changed and the programmer
can be started.

OFF: Program numbers cannot be

changed and the programmer
cannot be started.

- OFF

15.

Preventing the zigzag speed from
being changed

ON: Changes are prevented
OFF: Changes are allowed

- OFF

16.

Upper thread tension when sewing
underlays

ON: Strong (zigzag tension discs close)
OFF: Weak (zigzag tension discs open)

- OFF

17.

(*2)

Checking the needle up stop

position after sewing

ON: No
OFF: Yes

- OFF


(*1)… Memory switch No. 07. 08. 09.

(*2)… When memory switch No. 17 is set to ON, error code E-62 may be displayed. If this happens, check the entry for

error code E-62 in “14. Error code table”.

2188Q

Work clamp raised
ON position

No. 07.

Neutral position

Work clamp lowered ON position

Machine start ON position

No. 09.

No. 08.

Advertising