Brother HE-800A User Manual

Page 96

Advertising
background image

HE-800A

14. ERROR CODE TABLE

88

Code Cause

Remedy

E-92

Machine motor operation error

1. Turn off the power.
2. Turn the pulley by hand and check if the upper shaft locks

or not.

3. Check that connectors P3 and P6 on the main P.C. board

are properly connected.

4. Check that machine motor harness connector CN7 and

power supply harness connector CN8 on the 1-step power
supply circuit board are properly connected.

E-93

Blown solenoid fuse

1. Turn off the power.
2. Check fuse F1 on the main P.C. board. If it is blown

replace it.

E-94

Machine motor IC error

1. Turn off the power.
2. Turn the pulley by hand and check if the upper shaft locks

or not.

3. Check that connectors P3 and P6 on the main P.C. board

are properly connected.

4. Check that machine motor harness connector CN7 and

power supply harness connector CN8 on the 1-step power
supply circuit board are properly connected.

E-95

Power supply voltage error (high)

1. Turn off the power.
2. Check the power supply voltage in the workplace and the

power supply voltage specifications for the control box.

3. Check the connection positions of connectors CN2, CN3

and CN4 on the 1-step power supply circuit board.

࡮200V specification …CN2

࡮100V, 110V, 240V, 220V, 380V, 400V, 415V specifications

… CN3

࡮230V specification … CN4

E-96

Power supply voltage error (low)

1.

Turn off the power.

2.

Check the power supply voltage in the workplace and the
power supply voltage specifications for the control box.

3.

Check the connection positions of connectors CN2, CN3
and CN4 on the 1-step power supply circuit board.

࡮200V specification …CN2

࡮100V, 110V, 240V, 220V, 380V, 400V, 415V specifications

… CN3

࡮230V specification … CN4

E-97

Machine motor locked

࡮Excessive load during sewing.

࡮Motor temperature protection function
has operated. (If the motor's serial
number is "G03xxxxxx" or later)

1. Turn off the power.
2. Check if the timing belt is attached.
3. Turn the pulley by hand and check that the upper shaft

does not lock and the pulley is not loose.

4. Check that connectors P3 and P6 on the main P.C. board

are properly connected.

ArEA

Sewing data values exceed the needle
plate size or work clamp size which
have been set using the panel DIP
switches.

Three resetting methods are available depending on the
application.

A. By selecting a different program number (If you would like to

keep the program which exceeds the area.)

1. Press the SELECT key.
2. Select a different program number and press the

ENTER key.

If the data for the selected program number does not exceed
the sewing area, the error will be cleared.

B. By initializing the program

While pressing the ENTER key, press the RESET key.
All parameters (00 to 69) for the program will then be
initialized and the machine will switch to program mode.

C. By initializing all programs

Refer to "12-1. Initializing all programs".

If an error code that is not listed above appears or if carrying out the specified remedy does not solve the
problem, contact the place of purchase.

Advertising