Brother HE-800A User Manual

Page 90

Advertising
background image

HE-800A

13. CHANGING FUNCTIONS USING THE DIP SWITCHES

82

DIP switch B

No. ON/OFF

Setting

items

Default

ON -

1

OFF -

OFF

ON -

2

OFF -

OFF

ON

ޔONޔON Panel DIP switches B - No. 7 and No. 8 are enabled.

ON

ޔONޔOFF Work clamp size: 7.3 u 36.0 mm (Sewing area: 6.0 u 32.0 mm)

ON

ޔOFFޔON Work clamp size: 7.3 u 24.5 mm (Sewing area: 6.0 u 20.0 mm)

ON

ޔOFFޔOFF Work clamp size: 6.8 u 36.0 mm (Sewing area: 5.4 u 32.0 mm)

OFF

ޔONޔON Work clamp size: 6.8 u 24.5 mm (Sewing area: 5.4 u 20.0 mm)

OFF

ޔONޔOFF Panel DIP switches B - No. 7 and No. 8 are enabled.

OFF

ޔOFFޔON Work clamp size: 5.4 u 19.0 mm (Sewing area: 4.0 u 15.0 mm)

3

ޔ4ޔ5

OFF

ޔOFFޔOFF Panel DIP switches B - No. 7 and No. 8 are enabled.

OFF

ޔOFFޔOFF

ON

Needle plate size: 5.4 mm
(Max. needle zigzag feed width = 4.0 mm)

6

OFF

Needle plate size: 7.3 mm
(Max. needle zigzag feed width = 6.0 mm)

OFF

ON

ޔON

Work clamp size: 7.3

u 47.0 mm (Sewing area: 6.0 u 40.0 mm)

ON

ޔOFF

Work clamp size: 6.8

u 47.0 mm (Sewing area: 5.4 u 40.0 mm)

OFF

ޔON

Work clamp size: 5.4

u 24.5 mm (Sewing area: 4.0 u 20.0 mm)

7

ޔ8

OFF

ޔOFF

Work clamp size: 5.4

u 36.0 mm (Sewing area: 4.0 u 32.0 mm)

OFF

ޔOFF

* If the programs are initialized when Nos. 3, 4 and 5 are set to OFF, OFF and ON respectively, the initial value for

parameter No. 02 - Cutter size will be set to 6.0 mm. (Normal default value is 13.0 mm.)