Lukas SP 512 User Manual

Page 33

Advertising
background image

33

10.3.6 Mono-couplings

The mono-couplings must be replaced in the event of:
- external visible damage,
- the locking device not working,
- hydraulic

fl uid continually leaking in a coupled/uncoupled state.

During assembly, tighten the connection nut of the hose assembly with a torque of M

A

= 40 Nm.

Procedure:

1. Remove the cover from the couplings.

2. Loosen the connection nuts of the hose assembly and remove the coupling.

3. Position the new coupling and tighten the connection nuts of the hose assemblies

with a torque of M

A

= 40 Nm and push the cover of the couplings back on.

WARNING / CAUTION!
Never repair couplings: they are to be replaced by original LUKAS parts!

CAUTION!
Take care that the port ‘T’ of the rescue tool is always connected to the port ‘T’
of the mono-coupling.

Advertising
This manual is related to the following products: