1 MPa = 10 bar

**

Necessary volume of hydraulic fl uid in the hydraulic unit to operate the unit

(differential volume on piston / rod side)

type

SP 300

ref. no.

81-10-15

(111051000/171051000)

min. spreading force
(25mm / 0.98in. from the tips)

[kN]

36

[lbf.]

8090

max. spreading force

[kN]

125

[lbf.]

28100

spreading force HSF
(according to NFPA)

[kN]

40

[lbf.]

9000

spreading force LSF
(according to NFPA)

[kN]

33

[lbf.]

7419

max. spreading distance

[mm]

605

[in.]

23.8

max. pulling force (on mounting
borehole for chain set)

[kN]

31

[lbf.]

7000

pulling distance (on mounting
borehole for chain set)

[mm]

475

[in.]

18.7

pulling force HPF
(according to NFPA)

[kN]

24

[lbf.]

5400

pulling force LPF
(according to NFPA)

[kN]

20

[lbf.]

4500

dimensions
l x w x h

[mm]

750 x 355 x 255

[in.]

29.5 x 14.0 x 10.0

weight incl. hydraulic fl uid

[kg]

17,5

[lbs.]

38.6

max. operating pressure

[Mpa] *

70

[psi.]

10000

min. needed volume
of hydraulic fl uid

[l] **

0,14

[gal.-US]

0.04

coupling system

mono-coupling

classifi cation acc. to DIN EN 13204

AS36/605-18