11. Troubleshooting

Trouble

Control

Cause

Solution

Spreader arms move
slowly or jerkily when
activated

Are the hoses
connected
properly?

Air in the hydraulic
system

Deaerate pump
system

Does the pump
unit work?

Device doesn’t
perform at its given
power

Check the
hydraulic fl uid level
in the supplying
pump

Insuffi cient
hydraulic fl uid in
the pump

Top up hydraulic fl uid,
deaerate

Following release,
the star grip doesn’t
return to the central
position

Cover damaged
or star grip hard to
move?

Damage to the
torsion spring for
reset

Repair by an
authorised dealer, by
personnel specially
trained by LUKAS, or
by LUKAS itself

Soiled valve or
star grip

Defective valve
Other mechanical
damage (e. g. star
grip)

with mono-coupling-
system:
Hoses
cannot be coupled

Pressure too high
(e.g. caused by
too-high ambient
temperature)

Set hydraulic pump
to pressureless
circulation

Coupling defective Coupling needs to be

replaced immediately

with mono-
coupling-system:
It is frequently not
possible to couple
hose assemblies

Control the
degree of viscosity
and application
temperature of
the used hydraulic
fl uid

Hydraulic fl uid
not adapted to
the application
situation

Hydraulic fl uid
must be replaced
(see chapter
“Recommended
Hydraulic fl uids”)

Coupling defective Coupling needs to be

replaced immediately

with quick-
disconnect-coupling-
system:
Hoses
cannot be coupled

Is the pump
working?

Pressurized

Relieve pump

Coupling defective Coupling needs to be

replaced immediately

Hydraulic fl uid leak
on the hoses or the
fi xing-ins

Are the hoses
defective?

Leak, possible
damage

Replace hoses