Lukas SP 512 User Manual

Page 34

Advertising
background image

34

10.3.78 Valve cover

If the cover is deformed to such an extent that the star grip no long works correctly, the valve
must be replaced in its entirety.
Have repairs carried out by an authorised dealer, by personnel specially trained by LUKAS,
or by LUKAS customer service only.

10.3.7 Quick-disconnect-couplings

The quick-disconnect-couplings must be replaced in the event of:
- external visible damage,
- the locking device not working,
- hydraulic

fl uid continually leaking in a coupled/uncoupled state.

WARNING / CAUTION!
Never repair couplings: they are to be replaced by original LUKAS parts!

During assembly, tighten the connection nut of the hose assembly with a torque of M

A

= 35 Nm.

Procedure:

1. Loosen the connection nut of the hose assembly and remove the coupling.

2. Position the new coupling and tighten the connection nut of the hose assemblies

with a torque of M

A

= 35 Nm.

CAUTION!
The return hose, which is screwed onto the port “T” of the rescue tool, must be
equipped with a quick-disconnect-coupling (male) always.
However the supplying hose line must be equipped with a quick-disconnect-
coupling (female).

10.3.9 Labels

All damaged and/or illegible labels (safety notices, type plate, etc.) must be renewed.

Procedure:
1. Remove damaged and/or illegible labels.

2. Clean the surfaces using industrial alcohol.

3. Attach new labels.

Ensure that you attach the labels in the right position. If you are no longer sure about this,
then please contact your authorised LUKAS dealer or LUKAS itself.

Advertising