Lukas SP 512 User Manual

Page 39

Advertising
background image

39

*

1 MPa = 10 bar

**

Necessary volume of hydraulic fl uid in the hydraulic unit to operate the unit

(differential volume on piston / rod side)

type

SP 310

ref. no.

81-10-25

(111010000/171010000)

min. spreading force
(25mm / 0.98in. from the tips)

[kN]

46

[lbf.]

10300

max. spreading force

[kN]

308

[lbf.]

69200

spreading force HSF
(according to NFPA)

[kN]

55

[lbf.]

12400

spreading force LSF
(according to NFPA)

[kN]

44

[lbf.]

9890

max. spreading distance

[mm]

720

[in.]

28.3

max. pulling force (on mounting
borehole for chain set)

[kN]

41

[lbf.]

9200

pulling distance (on mounting
borehole for chain set)

[mm]

573

[in.]

22.6

pulling force HPF
(according to NFPA)

[kN]

32

[lbf.]

7200

pulling force LPF
(according to NFPA)

[kN]

25

[lbf.]

5600

dimensions
l x w x h

[mm]

783 x 345 x 192

[in.]

30.8 x 13.6 x 7.6

weight incl. hydraulic fl uid

[kg]

19,9

[lbs.]

43.9

max. operating pressure

[Mpa] *

70

[psi.]

10000

min. needed volume
of hydraulic fl uid

[l] **

0,24

[gal.-US]

0.07

coupling system

mono-coupling

classifi cation acc. to DIN EN 13204

AS46/720-20

Advertising
This manual is related to the following products: