Lukas SP 512 User Manual

Page 40

Advertising
background image

40

*

1 MPa = 10 bar

**

Necessary volume of hydraulic fl uid in the hydraulic unit to operate the unit

(differential volume on piston / rod side)

type

SP 510

ref. no.

111030000

81-10-30

(171030000)

min. spreading force
(25mm / 0.98in. from the tips)

[kN]

62

[lbf.]

13900

max. spreading force
(25mm / 0.98in. from the tips)

[kN]

230

[lbf.]

51706

spreading force HSF
(according to NFPA)

[kN]

79,9

[lbf.]

17962

spreading force LSF
(according to NFPA)

[kN]

54,6

[lbf.]

12275

max. spreading distance

[mm]

800

[in.]

31.50

max. pulling force (on mounting
borehole for chain set)

[kN]

55

[lbf.]

12365

pulling distance (on mounting
borehole for chain set)

[mm]

665

[in.]

26.18

pulling force HPF
(according to NFPA)

[kN]

44,4

[lbf.]

9982

pulling force LPF
(according to NFPA)

[kN]

31,1

[lbf.]

6992

dimensions
l x w x h

[mm]

900 x 380 x 215

[in.]

35.43 x 14.96 x 8.46

weight incl. hydraulic fl uid

[kg]

25

[lbs.]

55.1

max. operating pressure

[Mpa] *

70

[psi.]

10000

min. needed volume
of hydraulic fl uid

[l] **

0,43

[gal.-
US]

0.12

coupling system

Steckkupplung

Monokupplung

classifi cation acc. to DIN EN 13204

BS 62/800-25

Advertising