Trouble

Control

Cause

Solution

Especially by usage
of mono-couplings:
Leak on the handhold

check the
connections of the
hoses

hose connection
to the couplings
interchanged

reconnect the hoses
to the coupling in the
right way

Returnline
disabled

disconnect the
returnline from the
coupling, clean it and
reconnect it.

with mono-coupling-
system:
Leak in the
couplings

Is the coupling
damaged?

coupling damaged Coupling must be

replaced immediately

with quick-
disconnect-coupling-
system:
Leak in the
couplings

Is the coupling
damaged?

coupling damaged Coupling must be

replaced immediately

Is the leak only on
the coupling male?

Safety valve
reacted

After pressure
release there is no
more leakage.

12. Technical data

Since all values are subject to tolerances, minor differences may occur between the data on
your equipment and the data in the following schedules!

NOTE:
The following tables contain only the technical data required for standard
acceptance.
Additional data concerning your unit can be obtained from LUKAS on request.