SECTION 5 - MAST COMPONENTS

5-30

– JLG Lift –

3121231

5.12 MAST - 14 FT. HEIGHT LIMITING

SWITCH -15MSP (OPTION)

Ground Control Module Programming settings required:

• Set Ancillary 2 POL to HIGH (Up Arrow)

Location of Proximity Switch and Target

(Right side of mast from rear)

1. Proximity Switch

2. Target Plate

Proximity Switch Installation

1. Mounting Screws, Nuts

and Washers

2. Switch Shim

3. Proximity Switch

4. Harness Connector (a)

NOTE: (a) Proximity switch wiring is routed through hole in

the mast connect support to main harness "Aux 2
Input" connector (orange/red 49-6, black 13),
located under center rear cover on the left side of
the pump/motor.

Target Plate Installation

1. Target Plate

2. Mounting Screws and

Washers (a)

NOTE: (a) Secure to mast using existing holes.