Codes (300 - 399) Traction Control Module - Fault Condition

Check For These Obvious Conditions First:

• Damage to Traction Control Module wiring harness.
• Confirm that the static ground strap attached under base frame is secure and undamaged.

Table 6-42. Codes (300 - 399) Traction Control Module - Fault Condition

STEP

ACTION

SPEC

YES

NO

1.

Recycle machine power 5 times allowing a 10 second interval between
each power recycle. Does fault clear?

Done

Go to Step 2

2.

Is a code number displaying on the Ground Control Station?

Code - 316

Go to Step 3

Replace

Traction Control

Module

Code - 325

Go to Step 5

3.

Confirm that both installed batteries are 12 Volt DC.

12V DC

Go to Step 4

Replace with proper

Batteries

4.

Check battery voltage while charger is operating. Is voltage within specifi-
cation?

Maximum of

31 Volts DC

Replace

Traction Control

Module

Repair or Replace

Battery Charger

5.

Check for short in harness wires from Ground Control Station connector P5
to Traction Module (round din plug).
Note: This harness contains 6 wires only 3 are used, (See Figure 6-7.) Elec-
trical Diagram.

Repair or Replace

Wiring