SECTION 6 - TROUBLESHOOTING

3121231

– JLG Lift –

6-33

Code 38 - Battery Voltage Low - Warning Level 2 - Two (2) LED/LCDs lit

To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4
hours or until 8 bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level
2, batteries must be charged until 8 bars are lit on the ground station LCD display to clear the fault code. Failure to do so,
will result in a fault code 39.

Code 39 - Battery Voltage Low - Warning Level 3 - One (1) LED/LCDs lit

To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4
hours or until 8 bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level
1, batteries must be charged until 8 bars are lit on the ground station LCD display to clear the fault code.

3.

Check continuity of gate switches and foot switch circuit. (Switches are
wired in series; doors shut and foot switch depressed, circuit will be
closed)

Consult Factory

Replace Compo-

nent or Repair

Wires

Table 6-37. Code 35 - P2-Auxiliary #1 - Tie Down