SECTION 6 - TROUBLESHOOTING

6-24

– JLG Lift –

3121231

Code 14 - Pump Motor - Disconnected

Check For These Obvious Conditions First:

• Check the Positive (+)/Negative (–) cables from the Ground Control Module to the Pump Motor studs for loose or cor-

roded connections.

Code 15 - Lift Down Valve - Disconnected

Check For These Obvious Conditions First:

• Inspect wire terminals on the lift down valve at the base of the lift cylinder for tight and secure connection.

Table 6-18. Code 14 - Pump Motor - Disconnected

STEP

ACTION

SPEC

YES

NO

1.

Check resistance across the positive (+) and negative (–) studs on the
pump motor.

SeeTable 6-2

Replace Ground

Control Module

Repair or Replace

Pump Motor or
Motor Brushes

Table 6-19. Code 15 - Lift Down Valve - Disconnected

STEP

ACTION

SPEC

YES

NO

1.

Check voltage at the P1 connector on the Ground Control Module between
pin-10 and pin-3. Is reading within spec?

2 - 4 V DC

Replace Ground

Control Module

Go to Step 2

2.

Check resistance between the terminals on the lift down valve, located at
the base of the lift cylinder. Is reading within spec?

6 Ohms

Repair or Replace

Wiring Harness

from Ground

Control Module

Replace the

Lift Down Valve

Solenoid

3.

With the terminals still removed from the lift down valve coil, check continu-
ity of the wires from pins 10 and 3 on the P1 connector to the lift down valve.

.00 Ohms

Repair or Replace

Wiring