SECTION 6 - TROUBLESHOOTING

3121231

– JLG Lift –

6-9

1. Ground Control Module (a)

5. Traction Control Module (a)

9. Battery Disconnect (Option)

2. Left Side Battery (b)(c)

6. Power Cable To Left Drive Motor/Brake (a)

3. 175 Amp Fuse

7. Power Cable To Right Drive Motor/Brake (a)

4. Right Side Battery (b)(c)

8. Pump/Motor/Tank Assembly (b)

Ground Control

P1 - Horn, Alarm, Beacons, Lift Down Valve Harness (a)

P4 - Platform Junction Box Harness (a)

Module Plugs:

P2 - PHP, Elevation/Speed, Charger Limit Switch Harness (a) P5 - Joystick Protocol Harness (a)
P3 - Programmable Security Lock Harness (Option) (a)

Notes:

(a) Apply di-electric grease JLG Part Number 3020038 to wiring harness terminals, to prevent moisture from entering module.
(b) Seal NEG (–) and POS (+) posts with battery grease to prevent corrosion.
(c) See Section 4 - Figure 4-3. for the
optional (4) 6V battery cable connections.

Figure 6-5. Component Electrical Connections.

(+)

(–)

4

(+)

(+)

(+)

(–)

(–)

(–)

(–)

(+)

1

7

6

8

2

3

5

P1
P2
P5
P4
P3

M1

M2

9

Advertising