JLG 15/20MSP Service Manual User Manual

Page 132

Advertising
background image

SECTION 6 - TROUBLESHOOTING

6-12

– JLG Lift –

3121231

FAULT

CODE

PLATFORM

CONSOLE

LEDs

FLASHING

LCD SYMBOL SCREEN

LCD TEXT SCREEN

FAULT DESCRIPTION/
MACHINE CONDITION

FOR TROUBLESHOOTING

REFER TO

22

Horn or Horn Circuit Short

See Table 6-26,

Page 6-27

23

Horn Disconnected

See Table 6-27,

Page 6-28

24

Auxiliary #1 Circuit Short

See Table 6-28,

Page 6-28

25

Auxiliary #1 Circuit

Disconnected

SeeTable 6-29,

Page 6-29

26

Auxiliary #2 Circuit Short

See Table 6-30,

Page 6-29

27

Auxiliary #2 Circuit

Disconnected

See Table 6-31,

Page 6-30

30

6

Traction Module

No Communication

with Ground Control Module

See Table 6-32,

Page 6-30

31

Platform Control Console

No Communication with

Ground Control Module

See Table 6-33,

Page 6-31

32

7

Pump Motor Over Current

LIFT UP Disabled

See Table 6-34,

Page 6-31

33

2

Both PHP Bars UP

DRIVE and Lift UP Disabled

See Table 6-35,

Page 6-32

34

P2-Auxiliary #1 - Inhibit

LIFT UP/DOWN and DRIVE

are Disabled

See Table 6-36,

Page 6-32

35

P2-Auxiliary #1 - Tie Down

LIFT UP/DOWN and DRIVE

are Disabled

See Table 6-37,

Page 6-32

38

2

2 LEDs/BARS Flashing with

an audible beep.

Platform Lift-UP Function is

Locked Out.

See Page 6-33

Table 6-1. LCD Display - Service Fault Code Conditions

22

22

00000.0

23

23

00000.0

24

24

00000.0

25

25

00000.0

26

26

00000.0

27

27

00000.0

30

30

00000.0

31

31

00000.0

32

32

00000.0

33

33

00000.0

38

38

00000.0

Advertising