SECTION 6 - TROUBLESHOOTING

3121231

– JLG Lift –

6-35

Codes 41 thru 46 - OSS - Sensor 1 through 6 - Fault Condition

Check For These Obvious Conditions First:

• Is there an obstruction under the sensor showing the fault?
• Is the faulted sensor mounted properly and securely to the platform base frame?

Table 6-39. Codes 41 thru 46 - OSS - Sensor 1 through 6 - Fault Condition

STEP

ACTION

SPEC

YES

NO

1.

Is machine equipped with an OSS system?

Got to Step 4

Go to Step 2

2.

At the Ground Control Module, enter programming mode and view if OSS is
enabled. Is OSS enabled?

X = No

Go to Step 3

Replace Ground

Control Module

3.

In Service Level Programming mode, Disable Obstruction Senor System.

X=No

Go to Step 4

4.

Replace the sensor showing the fault. Does this correct the problem.

Done

Go to Step 5

5.

Replace the complete OSS system, module and sensors.